NEC 680.71 · Homes

Hydromassage bathtub circuits and GFCI

A hydromassage (jetted) bathtub needs its own individual branch circuit and a readily accessible GFCI. Receptacles of 125 V, 30 A or less within 6 ft of the tub need GFCI protection too.

What the code requires

A hydromassage bathtub, often called a jetted tub, and its electrical components must be on individual branch circuit(s) and protected by a readily accessible GFCI.

All 125-V, single-phase receptacles rated 30 A or less within 6 ft (1.83 m) horizontally of the tub's inside walls also need GFCI protection.

On the job

  • The tub must be on its own circuit, not shared with other bathroom loads.
  • Your inspector will check that the GFCI protecting the tub is readily accessible.
  • Check every receptacle within 6 ft of the tub, measured horizontally from its inside walls.
Bathroom vanity with a sink, mirror and medicine cabinet next to a tub
Bathroom vanity and sink (representative stock photo).

Related sections

Where this comes from

San Clemente · Dana Point · Laguna Beach

Send a photo. Get a real answer.

Text is fastest. If you smell something burning or see smoke, call 911 first and keep away from the panel.